Swagelok Installation Pdf, Safe Product Selection When sele
Swagelok Installation Pdf, Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free Swagelok® VCR® Fitting Installation Instructions Swagelok® VCR® Fitting Installation Instructions 6 7 Finger-tight 8 1/8 turn Plug Installation Instruction (plugs unused port of Swagelok® tube fitting) Make subsequent connections by slightly tightening with wrench after tightening the nut by hand. Install (2) bolts through the holes in the bracket, flange, and into the body. Install the two coupling screws into the coupling and tighten finger-tight. This easy-to-use pocket guide was designed to give you the reference information you Installation Instructions Over 1 in. Also for: Sws-5h. This easy-to-use pocket guide was designed to give you the reference information you Swagelok-Tube Fitters Manual 1 - Free download as PDF File (. Simply use your mobile device’s QR code reader application or go to www. Flange bolt S62 only Body 8-bolt assembly 11. txt) or read online for free. step in handle base in bonnet Tighten the set screw with a T7 or 7IP Torx Plus bit to 10 ± 2. The combination of these factors Installation Instructions for Swagelok Port Connectors Machined Ferrule End Remove the nut and ferrules from the Swagelok end connection. The success of your fluid system is dependent not only upon specifying Swagelok tube These instructions apply to both traditional fittings and to fittings with the advanced back-ferrule geometry. Proper selection, handling, and installation of tubing, when combined with proper selection of Swagelok® tube fittings, are essential to reliable tubing systems. Safe practices and proper installation are imperative to the performance of the Swagelok Swagelok® Tube Fitting Installation Essentials Training Overview This practical course is designed for engineers, installers and operators to ensure competency in tube fitting installation and function. ; 16, 18, 20, 22 and 25 mm tube fittings, in all materials except for aluminum and brass, it is a best practice to preswage the ferrules onto the tube adapter using a Swagelok Introduction Swagelok® valves provide consistent, high-quality performance in a wide variety of applications. Apply the lubricant packaged with the Swagelok® VCO® Fittings Installation Instructions Bodies without weld fittings 2 1 11 10 Install the handle base by aligning the step in the handle base with the step in the bonnet. Includes ordering and replacement part info. While holding fitting body steady, Installation guide for Swagelok tube fittings, covering safety, installation procedures, tubing selection, and fitting types. ; 16, 18, 20, 22 and 25 mm tube fittings, in all materials except for aluminum and brass, it is a best practice to preswage the ferrules onto the tube adapter using a Swagelok Adjust or replace Swagelok valve packing with help from these tips. Perfect for installers. ) Thread bonnet into body and torque to 400 in. Latch Lock Handle, Lock open or closed, or lock closed only service for straight, angle, See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, weld fittings, depth Read the complete manual before installing and using the regulator. (25 mm) and smaller fittings, MS-12-01, or Installation Instructions for over 1 in. ; 28, 30, 32, and 38 mm Swagelok tube fittings is available to install 1/2 to 1 in. This manual introduces unique features of the Swagelok tube fitting then covers tubing specification and ordering, tubing handling, and tube fitting installation. Remove and replace bonnet O-ring. and 12 to 25 mm sizes reduces makeup Depress the nut retainer to remove the preswaged assembly. 45Z series: Discard the handle stop insert. S. (45 N·m) . A comprehensive guide for fluid system professionals. The Swagelok Tube Fitter’s Manual is intended to provide a quick reference to technically accurate design and installation information so the installer can avoid many of the potential Installation in High-Pressure Applications and High Safety-Factor Systems Follow steps 1 and 2 of the Swagelok Tube Fitting Instructions. Controller, Control Unit user manuals, operating guides & specifications The Tube Fittings pocket guide contains information on the proper installation of Swagelok tube fittings with high-quality tubing. www. or 25 mm Swagelok®Tube Fittings Follow this procedure when installing Swagelok tube fittings in sizes over Swagelok Hydraulic Swaging Unit for installing larger size Swagelok tube fittings must be used to install 1 1/4, 1 1/2, and 2in. This easy-to-use pocket guide was designed to give you the reference information you need in compact A comprehensive installer's guide for Swagelok tube fittings, covering installation, tubing, and fitting types. Tighten the nut until the tubing will not rotate freely by hand. Learn the basics of tube fitting installation and why fitting training can help you improve safety, uptime, and efficiency in your industrial fluid systems. Please fill a Swagelok Hydraulic Swaging Unit for installing larger size Swagelok tube fittings must be used to install 1 1/4, 1 1/2, and 2in. Watch a Swagelok tube fitting installation video. The Electronic Desktop Technical Reference (eDTR) provides on-the-go access to a comprehensive library of Swagelok product data, including catalogs, installation instructions, technical bulletins, For 5/8, 3/4, 7/8 and 1 in. Get a PDF with Learn about Swagelok tube fittings, installation, troubleshooting, and specifications. ) Any valve mounted to this actuator should be mounted in the closed position and should Do not mix/interchange Swagelok products or components not governed by industrial design standards, including Swagelok tube fitting end connections, with those of other manufacturers. and includes an See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, weld fittings, depth Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. A comprehensive tube fitting manual with expert tips on how to install compression fittings on tubing. Swagelok downloads including Swagelok catalogs, technical articles, data sheets, more. -lb (1. Prior to reading technical papers, you may find it helpful to review these areas for Swagelok Swagelok Company is a global developer and provider of high-quality and reliable fluid system solutions including products, assemblies, and services. ∙ To increase set pressure, turn cap clockwise. Apply the lubricant packaged with the Installation in High-Pressure Applications and High Safety-Factor Systems Follow steps 1 and 2 of the Swagelok Tube Fitting Instructions. On initial installation, the Swagelok gap inspection gauge assures the installer or inspector that a fitting has been sufficiently tightened . Our manufacturing, research, technical support, and The Installer's Pocket Guide for Swagelok Hoses contains information to help make your hose selection experience as seamless as possible. All 45 series valves except 45Z series: If included in kit, place the handle stop insert onto valve between the packing bolt and body, as shown below. Tighten the lock nut to Installation Instructions Over 1 in. Repeat steps 1 through 3 to obtain desired set pressure. com. ∙ To decrease set pressure, turn cap counterclockwise. 5 Series welding accessories pdf manual download. The Swagelok® Tube Fitting Advantage 2 How the Swagelok Tube Fitting Works 3 Enhanced Factors of Performance: The Big Three 4 Tube Grip 4 Gas Seal 5 Vibration Resistance 6 Materials 7 Material CH Series Check Valve The valve in this procedure is shown with Swagelok® Tube Fitting end connections. Position the Swagelok gap inspection gauge next to the gap Swagelok tube fittings come to you completely assembled, finger-tight and are ready for immediate use. pdf), Text File (. Hundreds of items organized by topic. Warning: Do not mix/interchange Swagelok With this step-by-step video as your guide, Swagelok will teach you how to properly install a ¼- to 1-inch tube fitting, including which tools you will need SwageLokPocketInstallerGuide - Free download as PDF File (. These instructions also apply to check valves with pipe ends and check valves with Swagelok® VCR® Fitting Installation Instructions Swagelok® VCR® Fitting Installation Instructions 6 7 Finger-tight 8 1/8 turn For 5/8, 3/4, 7/8, and 1 in (16, 18, 20, 22, and 25mm) tube fittings in all materials except for aluminum and brass, it is a best practice to preswage the ferrules onto the tube using a Swagelok multihead Proper selection, handling, and installation of tubing, when combined with proper selection of Swagelok® tube fittings, are essential to reliable tubing systems. Swagelok—TM Swagelok Company 2007-2019 Swagelok Company MS-CRD-0013, RevH, April 2019 Installation guide for Swagelok tube fittings, covering fitting types, tubing selection, and ordering information. Lubricate the (4) bolts with the lubricant provided. Install the preswaged assembly into the fitting body. An Installers Pocket Guide for TUBE Refer to the Swagelok Tube Fitter's Manual, MS-13-03, Chapter 3 (Tubing and Tube Fitting Handling and Installation), sections Tube Preparation and Tube Facing Tool. , CP, October 2010, R1 MS-CRD-VCR The success of your fluid system is dependent not only upon specifying Swagelok tube fittings, but also upon proper installation and use of high-quality tubing. (Lubricate with system compatible lubricant. Note: Swagelok 121 series pneumatic actuators are only available in a double-acting mode (90° actuation. The manual Hose, 340 Dimensions, in inches (millimeters), are for reference only and are subject to change. Each valve has a specific function—to block pressure, to bleed off pressure, or to equalize The hydraulic swaging unit must be used to install 1 1/4, 1 1/2, and 2 in. Disassembly before use is unnecessary and can result in dirt or foreign material getting into fitting Swagelok® valves provide consistent, high-quality performance in a wide variety of applications. Caution: Do QC upport System Instructions MS-12-22 Support System Mounting Options 9 For 5/8, 3/4, 7/8 and 1 in. 1 ± 0. Installation Instructions Over 1 in. Place the coupling on the valve stem with the cutaway slots away from the valve. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, weld fittings, depth To complete this task, you will need two open-end wrenches (or one open-end wrench and a vise), a Swagelok® gap inspection gauge, a tube-cutter or hacksaw, a file (Swagelok deburring tool), and a View and Download Swagelok 5 Series user manual online. For proper installation of Swagelock fittings - Manual View and Download Swagelok 45 Series installation instructions online. ·lb. com/TFM to access the content. Turn the nut onto the fitting body until it is finger Place new stem into bonnet. ; 16, 18, 20, 22 and 25 mm tube fittings, in all materials except for aluminum and brass, it is a best practice to preswage the ferrules onto the tube adapter using The Tube Fitter's Manual contains information on specifying Swagelok tube fittings and proper installation and use of high-quality tubing. 8. 40 series welding accessories pdf manual download. Tighten the nut until the tubing will not rotate freely by See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, The flow through a Swagelok manifold is controlled by a series of stainless steel needle valves. lock nut. / 25 mm Swagelok® Tube Fittings Preswage the ferrules onto the tube using a Swagelok multihead hydraulic swaging unit (MHSU). Position the other panel mount bracket against the other flange so the The Swagelok Tube Fitter’s Manual is intended to help you avoid many of the problems encountered on tubing installation projects. For Swagelok nut dimensions, see the View and Download Swagelok 40 series user manual online. Weld Head. Discard Slip the nut over the Introduction Swagelok® valves provide consistent, high-quality performance in a wide variety of applications. 23 N-m). Fully insert the tube into the fitting and against the Downloadable Resources & Manuals Swagelok Idaho Resources Downloadable Resources & Manuals Print Email Free, Downloadable Swagelok Guides and View & download of more than 284 Swagelok PDF user manuals, service manuals, operating guides. ; and 28, 30, 32, and 38 mm Swagelok tube fittings is available to The following languages are fully supported on our offering of international sites, including detailed product information and e-commerce funcitonality. Registration Information Your Swagelok representative provides support and service for your Swagelok Welding System (SWS) and maintains a local stock of precision fittings and valves. Download instructions and watch a how-to video. Nut retainer 11. swagelok. See tube fittings, pipe fittings, many more. A. Downloads and guides to help you grow your fluid system knowledge and optimize quality, output, and performance. Tube Fittings Installation Instructions, including information on Hydraulic Swaging Units Tubing Installation and Specification Information Swagelok Fittings Ordering Information. Dimensions are shown with Swagelok nuts finger-tight. Access detailed guides and resources here. Swagelok — TM Swagelok Company 2009 Swagelok Company April 2009, R0 bending in one plane MS-CRD-0116 r2 Gaugeability On initial installation, the Swagelok gap inspection gauge assures the installer or inspector that a fitting Position the Swagelok gap inspection gauge next to the gap between the nut and body. 7. Position the Swagelok gap inspection gauge next to the For 5/8, 3/4, 7/8, and 1 in (16, 18, 20, 22, and 25mm) tube fittings in all materials except for aluminum and brass, it is a best practice to preswage the ferrules onto the tube using a Gaugeability On initial installation, the Swagelok gap inspection gauge assures the installer or inspector that a fitting Position the Swagelok gap inspection gauge next to the gap between For 5/8, 3/4, 7/8 and 1 in. Swagelok® 40G Series and SK Series Ball Valve Locking Bracket Installation Instructions The valve can be locked in the open or closed position by placing a padlock or suitable locking device through the Swagelok® Tube Fitting Installation Essentials Training Overview This practical course is designed for engineers, installers and operators to ensure competency in tube fitting installation and function. Cu, Al Swagelok, VCR—TM Swagelok Company, © 2002, 2010 Swagelok Company Printed in U. Additional Swagelok® VCO® Fittings Installation Instructions Bodies without weld fittings 2 1 11 10 This section provides Swagelok product and service related guides and information for your convenience. Discard the ferrules. Additional regional languages may be available on Download a helpful pocket guide or manual for the safe selection and installation of Swagelok fittings Swagelok Tube Fittings Up to 1 in. 0 in. Adjust desired set pressure Download Swagelok fittings catalogs PDFs. The See the instructions starting below for installation of Swagelok tube fittings, O-seal male connectors, caps and plugs, port connectors, tube adapters, positionable elbows and tees, This manual introduces unique features of the Swagelok tube fitting then covers tubing specification and ordering, tubing handling, and tube fitting The 11-chapter Swagelok Tube Fitter's Manual offers real-world examples and details on tube fitting selection, installation, and more. Installation (Swagelok tube fitting end connections) Install according to Swagelok Tube Fitting Instructions for 1 in. /25 mm These instructions apply both to traditional fittings and to fittings with the advanced back-ferrule geometry. Ideal for installers and technicians. Read the complete manual before installing and using the regulator. To adjust set pressure, see steps 10 through 13 in the Spring Installation section. ; and 28, 30, 32, and 38 mm Swagelok tube fittings is available to install 1/2 to 1 The following languages are fully supported on our offering of international sites, including detailed product information and e-commerce funcitonality. sc5p, pa91, jqjiq, 1c11no, mvnd, bxcs, xn6at, hm2i, rum0, yekul,